× The internal search function is temporarily non-functional. The current search engine is no longer viable and we are researching alternatives.
As a stop gap measure, we are using Google's custom search engine service.
If you know of an easy to use, open source, search engine ... please contact support@midrange.com.



Try looking at data area's:      
        SSASYS      BPCSF       BPCS System Control Data Area
      SSASYS2     BPCSF       BPCS System Control Data Area - Part 2


-----Original Message-----
From: bpcs-l-bounces+ssegerstrom=intermatic.com@xxxxxxxxxxxx
[mailto:bpcs-l-bounces+ssegerstrom=intermatic.com@xxxxxxxxxxxx]On Behalf
Of Michael DeGennaro
Sent: Friday, July 22, 2005 8:55 AM
To: SSA's BPCS ERP System
Subject: RE: [BPCS-L] BPCS test system


Sev       Type    Text                    Program     
 30        DIAG    Message not sent. ACP29 QMHSNBRK    
                   0B in *LIBL not work st             
                   ation message queue.                
 40        ESC     Error occurred when sen QMHSNBRK    
                   ding message.                       
 40        ESC     Function check. CPF2469 QMHUNMSG    
                    unmonitored by SYS656C             
                   C at statement *N, inst             
                   ruction X'003C'.                    
                             Variables                 
                                                       

Also 
Call IIT031E
Cannot resolve to object NWICSTUB *pgm not found
Sndbrkmsg  ('security violation') tomsgq(SSATCP) SSATCP not work station
message queue not sent.....  

Michael De Gennaro


-----Original Message-----
From: bpcs-l-bounces+miked=teltronics.com@xxxxxxxxxxxx
[mailto:bpcs-l-bounces+miked=teltronics.com@xxxxxxxxxxxx] On Behalf Of
Jim Mergen
Sent: Friday, July 22, 2005 9:48 AM
To: SSA's BPCS ERP System
Subject: RE: [BPCS-L] BPCS test system

What is the message you are receiving?

-----Original Message-----
From: bpcs-l-bounces+jmergen=pctcnet.net@xxxxxxxxxxxx
[mailto:bpcs-l-bounces+jmergen=pctcnet.net@xxxxxxxxxxxx]On Behalf Of
Michael DeGennaro
Sent: Friday, July 22, 2005 8:38 AM
To: SSA's BPCS ERP System
Subject: RE: [BPCS-L] BPCS test system


I created a duplicate object of the BPCSF604 library 
To testf604 and copied the files ZSC,ZXM,ZXO,ZXP,ZXU and ZMA from a copy
of my old test data, that was working.

I get a security violation when a try to run anything.
Is there something missing like a dataara etc????

Thanks
Michael De Gennaro


-----Original Message-----
From: bpcs-l-bounces+miked=teltronics.com@xxxxxxxxxxxx
[mailto:bpcs-l-bounces+miked=teltronics.com@xxxxxxxxxxxx] On Behalf Of
Dan Sweeney
Sent: Thursday, July 14, 2005 9:17 PM
To: 'SSA's BPCS ERP System'
Subject: RE: [BPCS-L] BPCS test system

I disagree SSASYS and SSASYS2 data areas are in the files library and
not the object library. You are correct you did over simplify the issue.

-----Original Message-----
From: bpcs-l-bounces+dsweeney=phoenixbcinc.com@xxxxxxxxxxxx
[mailto:bpcs-l-bounces+dsweeney=phoenixbcinc.com@xxxxxxxxxxxx] On Behalf
Of Steve Segerstrom
Sent: Thursday, July 14, 2005 6:42 PM
To: SSA's BPCS ERP System
Subject: RE: [BPCS-L] bpcs test system

We are bpcs 6.04. 

We have a pretty straightforward set-up and this is probably an
oversimplification. SO WARNING -  there may be other issues that you
have that we would not.

For us we have two data libraries (Native BPCS and our customer files).
We ONLY restore these data libraries; with the exception of these files:

        ZSC ZXM ZXO ZXP ZXU ZMA
This comes with a cost ; occasionally folks put something in these files
in production and don't have the same entries in test system

Source moves from our test to production so we don't move programs.

We use the same data areas in production as in test. 

Data areas for BPCS are in our program libraries.

The only real problems we have had is if someone has a test file not
promoted (they have to set up the file again) or if they have not
promoted a sys105 table (it will be lost). We announce the move loudly
and clearly and really only do several per year.

-----Original Message-----
From: bpcs-l-bounces+ssegerstrom=intermatic.com@xxxxxxxxxxxx
[mailto:bpcs-l-bounces+ssegerstrom=intermatic.com@xxxxxxxxxxxx]On Behalf
Of Michael DeGennaro
Sent: Thursday, July 14, 2005 3:47 PM
To: bpcs-l@xxxxxxxxxxxx
Subject: [BPCS-L] bpcs test system


Does anybody know how to move production files 
To a test environment with out messing up the test 
User profiles and security files etc.? Need to get 
Production data files only with out the security files,
Data area's, etc. 
 
Michael De Gennaro
 

As an Amazon Associate we earn from qualifying purchases.

This thread ...


Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.