Check your work station addresses to make sure you do not have two people with something like QDEV00000 some address that is in violation of the mixed mode rules. You can get at this with DSPJOB focused on recent sessions with such addresses. We have some rules for attaching work stations so that they have unique addresses in the first 6-7 characters because BPCS strips off the last 1-2 characters for keeping track of work areas by application. But sometimes people, who are not familiar with all the rules, try to connect a PC to the 400 network, and we end up with PC & 400 & other defaults not being over-ridden. So then you have two or more people whose work station addresses as far as BPCS is concerned is the same work area. Garbage in Garbage out. MacWheel99@aol.com (Alister Wm Macintyre) (Al Mac)
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].