*OMITLIB set to *DELETE.
*DELETE
Exclude deleted libraries from the recovery. Please note that only
libraries deleted before the last run of Start Maintenance for BRM
(STRMNTBRM) will be omitted.
It "appears" that *DELETE is not WAD.
STRMNTBRM is run daily on all LPARS.
Paul
-----Original Message-----
From: MIDRANGE-L [mailto:midrange-l-bounces@xxxxxxxxxxxxxxxxxx] On Behalf Of Rob Berendt
Sent: Thursday, May 30, 2019 3:54 PM
To: Midrange Systems Technical Discussion
Subject: RE: STRRCYBRM *SYSTEM *RESTORE - time period for recovery recommendations
Did you read the help on *OMITLIB?
If so, how often do you run STRMNTBRM?
On one of my systems:
WRKJOBSCDE BRM*
Next
-----Schedule------ Recovery Submit
Job Status Date Time Frequency Action Date
BRMMAINT SCD *ALL 06:45:00 *WEEKLY *SBMRLS 05/31/19
BRMRECOVER SCD USER DEF 06:30:00 *WEEKLY *NOSBM 05/31/19
BRMREORG SCD *MONTHSTR 00:01:00 *MONTHLY *SBMRLS 06/01/19
Command . . . . . . . . . . . : STRMNTBRM RMVMEDI(*REUSE) PRTEXPMED(*NO) PRT
VSNRPT(*NO) PRTBKUACT(*NO) PRTRCYRPT(*RCYANL *SAVEXCP)
BRMRECOVER is a custom program which creates the BRMS recovery report and stores it as a PDF on three geographically dispersed servers.
The "weekly" entries run all 5 working days.
-----Original Message-----
From: MIDRANGE-L <midrange-l-bounces@xxxxxxxxxxxxxxxxxx> On Behalf Of Steinmetz, Paul via MIDRANGE-L
Sent: Thursday, May 30, 2019 2:23 PM
To: 'Midrange Systems Technical Discussion' <midrange-l@xxxxxxxxxxxxxxxxxx>
Cc: Steinmetz, Paul <PSteinmetz@xxxxxxxxxx>
Subject: STRRCYBRM *SYSTEM *RESTORE - time period for recovery recommendations
When doing a STRRCYBRM *SYSTEM *RESTORE, what are the recommendations for Time period for recovery?
1) Let it default as below, *BEGIN *END?
2) Or should you reference your last system save?
3) Other options?
I found in testing that when you let it default, it includes libraries that are no longer on the system, from old saves that are not expired.
Start time and date:
Beginning time . . . . . . . . *AVAIL
Beginning date . . . . . . . . *BEGIN
End time and date:
Ending time . . . . . . . . . *AVAIL
Ending date . . . . . . . . . *END
Thank You