message: 1
date: Mon, 19 Mar 2018 15:29:02 -0300
from: Roberto Jos? Etcheverry Romero <yggdrasil.raiker@xxxxxxxxx>
subject: Re: Connect Ops Console and/or DST on Bare Metal
Quick input. HMC=0/1 means that the machine WAS connected to an HMC. You
will have to erase that configuration to be able to use it in single-lpar
mode. The machine might not even support IBM i, it's detailed inside the
ASMI in one of the tabs (IBM i capable and 5250 capable or something like
that).
I would take care removing cpu-cards without putting the fillers in.
Airflow on the newer machines is very tightly calculated and a missing card
or filler might cause overheating.
Best regards!
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].