|
STRSST
8. Work with service tools user IDs and Devices 3. Select console
Select one of the following:
Console type . . . . . . . . . . . . . . . . 4
1. Twinaxial
2. Operations console(Direct)
3. Operations console(LAN)
4. Hardware management console(HMC)
Current state of console tag . . . . . . . . 4
How do you know you do not have a system console? For the love of God
please don't tell me because you can't seem to find a twinax cable
coming out of the box.
Follow the following instructions and tell me what you have for
"Current state of console tag".
STRSST
8. Work with service tools user IDs and Devices 3. Select console
Select one of the following:
Console type . . . . . . . . . . . . . . . . 4
1. Twinaxial
2. Operations console(Direct)
3. Operations console(LAN)
4. Hardware management console(HMC)
Current state of console tag . . . . . . . . 4
No, you do NOT need to set it to manual to power it off.
do the following:
PWRDWNSYS DELAY(120) RESTART(*YES) IPLSRC(B) DSPJOBLOG OUTPUT(*PRINT)
SIGNOFF *LIST After two minutes it will start the power off, then
power itself on again.
Repeat after me.
This is not an AS/400.
It should be a once in a system's lifetime thing that I ever hit the
buttons on the front of the box. Ever. Even if I've pulled the plug,
I should not have to use the buttons to start it from scratch.
Rob Berendt
--
IBM Certified System Administrator - IBM i 6.1 Group Dekko Dept 1600
Mail to: 2505 Dekko Drive
Garrett, IN 46738
Ship to: Dock 108
6928N 400E
Kendallville, IN 46755
http://www.dekko.com
From: "Hopkins, William" <William.Hopkins@xxxxxxxxxxxxxxxxx>
To: "midrange-l@xxxxxxxxxxxx" <midrange-l@xxxxxxxxxxxx>
Date: 01/19/2016 01:56 PM
Subject: No system console and TCP/IP down
Sent by: "MIDRANGE-L" <midrange-l-bounces@xxxxxxxxxxxx>
Hi All,
First note I am not a hardware person.
We have a IBMi 720 Express on v7r1 that TCP/IP needs to be ended and
restarted.
The problem is there is no system console setup.
What are the steps I should follow to power it off manually and IPL?
I know I need to set it to manual so it will allow the power off.
Any know gotchas here?
Also what are the requirements for the PC to be used as the System
Console when we set one up?
Please forgive me for my lack of knowledge and thanks ahead of time
for helping out.
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing
list To post a message email: MIDRANGE-L@xxxxxxxxxxxx To subscribe,
unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx Before posting, please take
a moment to review the archives at
http://archive.midrange.com/midrange-l.
Please contact support@xxxxxxxxxxxx for any subscription related
questions.
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing
list To post a message email: MIDRANGE-L@xxxxxxxxxxxx To subscribe,
unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx Before posting, please take
a moment to review the archives at
http://archive.midrange.com/midrange-l.
Please contact support@xxxxxxxxxxxx for any subscription related
questions.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.