Drive replaced.
Concurrent maintenance fails the drive if not already failed.
Paul
-----Original Message-----
From: MIDRANGE-L [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Steinmetz, Paul
Sent: Monday, July 13, 2015 10:22 AM
To: 'Midrange Systems Technical Discussion'
Subject: V7R1 replacing a non-failed 19A3 10k spinny drive in P7 CEC - RAID 5 no hot spare
Had a 19A3 10k spinny drive in P7 CEC call home twice this weekend.
Drive still not fail, but is being replaced later this afternoon.
Is there extra step involved when replacing a non failed drive, drive still shows active?
V7R1 19A3 10k spinny drive in P7 CEC - RAID 5 no hot spare Something like force failing the drive first.
Parity Resource Hot Spare
Set ASP Unit Type Model Name Status Protection
1 57CB 001 DC07 RAID 5 N
1 4 19A3 099 DMP051 Active
1 5 19A3 099 DMP050 Active
1 2 19A3 099 DMP049 Active
1 8 19A3 099 DMP056 Active
1 6 19A3 099 DMP054 Active
1 7 19A3 099 DMP053 Active
1 1 19A3 099 DMP055 Active
1 3 19A3 099 DMP052 Active
Drive began reporting PAL entries back on 05/28/15.
Reached a threshold on 07/10/15
19A3FFF7 05/28/15 07:04:20 Temp DMP056 19A3
19A3FFF9 05/31/15 02:28:19 Temp DMP056 19A3
Date Count
07/10/15 . . . . . . . . . . . . . . . . . . 158
07/11/15 . . . . . . . . . . . . . . . . . . 8
07/12/15 . . . . . . . . . . . . . . . . . . 4
Thank You
_____
Paul Steinmetz
IBM i Systems Administrator
Pencor Services, Inc.
462 Delaware Ave
Palmerton Pa 18071
610-826-9117 work
610-826-9188 fax
610-349-0913 cell
610-377-6012 home
psteinmetz@xxxxxxxxxx
http://www.pencor.com/
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list To post a message email: MIDRANGE-L@xxxxxxxxxxxx To subscribe, unsubscribe, or change list options,
visit:
http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx Before posting, please take a moment to review the archives at
http://archive.midrange.com/midrange-l.
As an Amazon Associate we earn from qualifying purchases.