Hey Pete isn't the 2793 the same card as the 2893 but placed next to an IOP?

- L


Pete Massiello wrote:
*This message was transferred with a trial version of CommuniGate(r) Pro*
Rob,

Something isn't right. A 2793 requires an IOP, and you don't have
IOPs in a Power 6 box. Are you sure it isn't a 2893? A 6803 or a 6805?

Pete

Pete Massiello
iTech Solutions
http://www.itechsol.com

Add iTech Solutions on Facebook:
http://www.facebook.com/group.php?gid=126431824120
Add iTech Solutions on LinkedIn: http://www.linkedin.com/groups?gid=2206093


-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx
[mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of rob@xxxxxxxxx
Sent: Thursday, December 03, 2009 10:03 AM
To: Midrange Systems Technical Discussion
Subject: Re: Will a 2793 2 line WAN card go into C1 of a system unit on a
power 6 570-MMA?

Contacted the BP. He said leave the 2793 in C5 and put the future 5749 in C4.


Rob Berendt

As an Amazon Associate we earn from qualifying purchases.

This thread ...

Replies:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.