I had a library that failed STROBJCVN that passed ANZOBJCVN. This is fun
news after a V6R1 upgrade.
The name of the library was "DUH" so I am assuming that it's nothing
important.
Creation information:
Creation date/time . . . . . . . . . : 08/08/01 09:33:04
Created by user . . . . . . . . . . : ROB
System created on . . . . . . . . . : GDISYS
Object domain . . . . . . . . . . . : *SYSTEM
STROBJCVN LIB(DUH)
Digital signature lost for object EVFAAHDL.
State of object EVFAAHDL changed to *USER.
Digital signature lost for object EVFADSPC.
State of object EVFADSPC changed to *USER.
Digital signature lost for object EVFAESCP.
State of object EVFAESCP changed to *USER.
Digital signature lost for object EVFAHBKP.
State of object EVFAHBKP changed to *USER.
Digital signature lost for object EVFAHTRC.
...
Not all objects were converted.
CPIB0DC
Message . . . . : Digital signature lost for object EVFACODE.
Cause . . . . . : Object EVFACODE of type *SRVPGM in library DUH was
digitally signed.
The conversion process creates a new version of the object. The
digital
signature has been removed from the object. The digital signature could
not
be preserved because it applied to the old object format, and the object
was
re-formatted during the conversion process.
Recovery . . . : In order to have a digital signature again then refer
to
"Object signing and signature verification" in the Security topic in the
i5/OS Information Center at
http://www.ibm.com/systems/i/infocenter/.
CPIB0E3
Message . . . . : State of object EVFACODE changed to *USER.
Cause . . . . . : During conversion processing, object EVFACODE of type
*SRVPGM in library DUH was changed to *USER state.
Recovery . . . : There is no recovery. Only IBM can create *SYSTEM
state
and *INHERIT state programs.
CPFB0E2
Message . . . . : Not all objects were converted.
Cause . . . . . : Start Object Conversion(STROBJCVN) OPTION(*CONVERT)
could
not finish successfully.
14 objects were not converted. 40 objects located in DUH have been
converted by STROBJCVN.
0 objects were not converted. 0 objects located in *N have been
converted
by STROBJCVN.
If *N or 0 appears for any fields, then this information does not
apply.
Recovery . . . : Display the Job Log (DSPJOBLOG) to see previous
message.
Perform the recovery indicated in the previous messages, and try the
request
again.
I got a whole lot more than 14 copies of CPIB0E3.
Random object sample
System level . . . . . . . . . . . . : V5R1M0
Compiler . . . . . . . . . . . . . . : CRTPGM V5R1M0
Licensed program . . . . . . . . . . : 5722WDS V5R1M0
I wouldn't have thought that V5R1 would have had an issue with ANZOBJCVN.
Rob Berendt