Hi Folks,

 

Had a BIG problem during EOD processing early this morning. In a batch job
the command was issued to shut QINTER down and it hung with ONE stinking
job. This job was spitting out CPI2417 Job message queue for
xxxxxx/xxxxxx/xxxx has been wrapped. like CRAZY. So our vendor software
checks for QINTER to be down and tries to end it and for some reason that
bombed.

 

Cut to the chase here, what the heck is going on when one stinking job can
keep QINTER from ending ? This is an iSeries 810 at V5V2.

 

I have looked that the system values and their settings are as follows:

 

QJOBMSGQFL - *NOWRAP

QJOBMSGQMX  - 24

QJOBMSGQSZ  - 16

QJOBMSGQTL - 24

 

What do I do about this ?

 

Thanks in advance !

 

Chuck


As an Amazon Associate we earn from qualifying purchases.

This thread ...

Follow-Ups:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].