True, the SCSI cards would lose their minds and need to be booted. If they
were controlled by an IOP then the IOP had to reboot as well. If that IOP
controlled disk, just IPL the box. I'm doubting that situation exists here
since Paul tends to have newer equipment that most likely does not have
IOPs.

--
Jim Oberholtzer
Chief Technical Architect
Agile Technology Architects


-----Original Message-----
From: MIDRANGE-L [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of
rob@xxxxxxxxx
Sent: Monday, August 25, 2014 1:22 PM
To: Midrange Systems Technical Discussion
Subject: RE: Tape Library 3573 error - 9E - Elevator range out specification

Jim has a point there.

Another thing is that there are some brain cells in the wayback machine
telling me that, on occasion, I had to 'ipl' the card(s) {using SST} going
to the tape drive(s) upon replacement. Something tells me that was mainly
with SCSI attached 3581's with LTO 1 drives.


Rob Berendt
--
IBM Certified System Administrator - IBM i 6.1 Group Dekko Dept 1600 Mail
to: 2505 Dekko Drive
Garrett, IN 46738
Ship to: Dock 108
6928N 400E
Kendallville, IN 46755
http://www.dekko.com





From: "Jim Oberholtzer" <midrangel@xxxxxxxxxxxxxxxxx>
To: "'Midrange Systems Technical Discussion'"
<midrange-l@xxxxxxxxxxxx>
Date: 08/25/2014 02:14 PM
Subject: RE: Tape Library 3573 error - 9E - Elevator range out
specification
Sent by: "MIDRANGE-L" <midrange-l-bounces@xxxxxxxxxxxx>



What Rob is trying to say is we are unaware of any way to save/restore the
library configuration. Be ready to hand configure the new one if it comes
to that. There was a way on the big 3594s to save the config and update
it
but I don't know if that option exists on the smaller libraries.

As to firmware, while I agree being on the latest version is good, the
reality is you should match what you have today until you verify that
after
replacement it works. Then take the time to update it and re-verify it
works. That way if there's a problem you won't be fighting multiple
change
modalities.

--
Jim Oberholtzer
Chief Technical Architect
Agile Technology Architects


-----Original Message-----
From: MIDRANGE-L [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of
rob@xxxxxxxxx
Sent: Monday, August 25, 2014 12:29 PM
To: Midrange Systems Technical Discussion
Subject: RE: Tape Library 3573 error - 9E - Elevator range out
specification

I would download:
latest library firmware
latest drive firmware
and be prepared to update those. IBM normally loads up replacement
libraries and drives with the latest firmware. However, if they've been
on
the shelf too long they may get dated.
You may want to step through the configuration manually and be prepared to
reenter it all. IP addresses and all. You do have remote access to it
via
a web browser, right? Screen shots to Power Point will work quite well.


Rob Berendt
--
IBM Certified System Administrator - IBM i 6.1 Group Dekko Dept 1600 Mail
to: 2505 Dekko Drive
Garrett, IN 46738
Ship to: Dock 108
6928N 400E
Kendallville, IN 46755
http://www.dekko.com





From: "Steinmetz, Paul" <PSteinmetz@xxxxxxxxxx>
To: "'Midrange Systems Technical Discussion'"
<midrange-l@xxxxxxxxxxxx>
Date: 08/25/2014 01:11 PM
Subject: RE: Tape Library 3573 error - 9E - Elevator range out
specification
Sent by: "MIDRANGE-L" <midrange-l-bounces@xxxxxxxxxxxx>



CE coming on site to replace the entire library, if he can't get the
robot/picker to move.
Where is the library configuration stored?



-----Original Message-----
From: MIDRANGE-L [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of
DrFranken
Sent: Monday, August 25, 2014 11:25 AM
To: Midrange Systems Technical Discussion
Subject: Re: Tape Library 3573 error - 9E - Elevator range out
specification

You rolled the UPS into the elevator with all the batteries in it and now
it's out of range? :-) [Yes seen it done....]

You didn't say how big your 3573 is but it would appear that it's 'lost'
in the vertical dimension. So a sensor failure or dust in there or loose
wire. In any case most likely the repair guy is your best bet here.

- Larry "DrFranken" Bolhuis

www.frankeni.com
www.iDevCloud.com
www.iInTheCloud.com

On 8/25/2014 9:55 AM, Steinmetz, Paul wrote:

Anyone ever experience a 9E on a 3573, Elevator range out specification.


9E: HE: invalid elevator range
09: error during elevator init
00: unspecified command

Thank You
_____
Paul Steinmetz
IBM i Systems Administrator

Pencor Services, Inc.
462 Delaware Ave
Palmerton Pa 18071

610-826-9117 work
610-826-9188 fax
610-349-0913 cell
610-377-6012 home

psteinmetz@xxxxxxxxxx
http://www.pencor.com/

--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing
list To post a message email: MIDRANGE-L@xxxxxxxxxxxx To subscribe,
unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx Before posting, please take a
moment to review the archives at http://archive.midrange.com/midrange-l.


As an Amazon Associate we earn from qualifying purchases.

This thread ...

Follow-Ups:
Replies:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.