I did some research on the system I applied TR 6 and the latest group PTFs on just yesterday. I also used the insptf command with instyp(*dlyall), but I IPL'ed immediately after. I found 2 new PTFs that got applied temporarily right before the IPL.
5770BR1-SI47935 loaded at 09:54 and temporarily applied at 10:18
5770DG1-SI48830 loaded at 09:55 and temporarily applied at 10:19
I am very interested to hear the response back to Rob's PMR.
-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Jim Oberholtzer
Sent: Tuesday, March 05, 2013 9:45 AM
To: Midrange Systems Technical Discussion
Subject: Re: PTF apply, DLYALL, brms ralphed.
My guess is that some of the BRMS functions are active when the PTF is
applied. Might be an exit program, or a monitor that's running. If
those were all stopped prior to a BRMS PTF being applied all should be
well. I'm just annoyed that I can't apply the groups/cumulative with
option 8, do not IPL, and wait for the scheduled IPL over the weekend to
do it.
Jim Oberholtzer
Chief Technical Architect
Agile Technology Architects
On 3/5/2013 10:39 AM, rob@xxxxxxxxx wrote:
Another significant situational fact:
From the joblog of the backup:
SQ99999-03/04/13 22:24:49
From the joblog of the INSPTF:
03/04/13 21:19:59 - INSPTF LICPGM((*ALL)) DEV(OPTVRT01) INSTYP(*DLYALL)
...
03/04/13 21:24:34 - Object QSI47935J1 in QSRV type *FILE renamed
QPZR002197.
...
03/04/13 21:24:45 - PTF 5770BR1-SI47935 V7R1M0 loaded into library QBRM.
...
03/04/13 22:25:27 - PTF 5770BR1-SI47935 V7R1M0 temporarily applied to
library
Perhaps these times conflicted?
Rob Berendt
-- IBM Certified System Administrator - IBM i 6.1 Group Dekko Dept
1600 Mail to: 2505 Dekko Drive Garrett, IN 46738 Ship to: Dock 108
6928N 400E Kendallville, IN 46755 http://www.dekko.com
--