It's a shame CPYF doesn't have a *NONE option for member. The appropriate way to copy a logical would be to CPYF FROMFILE(FROMLIB/ORIGINAL) TOFILE(TOLIB/ORIGINAL) FROMMBR(*NONE) CRTFILE(*YES) and then ADDLFM to point the logical to the appropriate physical. That way, you'd always be sure your copied logical pointed to the physical you want.

I have deleted the members of a logical (RMVM), copied it, and then ADDLFM to both the original and the copy. You have to DSPFD the logical first to see where the members are currently pointing (based on file). Note that RMVM doesn't work if the logical was created as an SQL view.

-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Gary Thompson
Sent: Saturday, September 29, 2012 1:27 PM
To: Midrange Systems Technical Discussion
Subject: RE: confusion with logical files and crtdupobj

Jeffrey, your points are well taken.

I agree, using CRTDUPOBJ is something like "carving soap with a razor blade",
and checking DB Relations to verify results is a best practice for all
LF create actions (DDS and/or SQL), but I actually do trust CRTDUPOBJ,
but do not trust >me<.


-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Jeffrey Tickner
Sent: Saturday, September 29, 2012 12:07 PM
To: midrange-l@xxxxxxxxxxxx
Subject: Re: confusion with logical files and crtdupobj

CRTDUPOBJ and LFs will not always work. Speaking from over 14 years in CM on i where CRTDUPOBJ is a common method for putting objects in place on the production server, you JUST CAN'T TRUST IT. I would normally recommend that LFs be the only object type that the source was sent over and the object compiled into place. Had one customer who did NOT have any compiler installed on the production server, yes they had problems.
If you look at the help on CRTDUPOBJ IBM qualifies what will happen with LFs and describes exactly what happened in your case.

When a logical file is copied into another library, two cases
determine the basing for the file:

1. If both the logical file and its based-on physical file are
originally in the same library, a duplicate of the physical
file must be created in the new library before a duplicate of
the logical file is created. After these two duplicates are
created, the new logical file is based on the new physical
file.

2. If the logical file and its based-on physical file are
originally in different libraries, it is not necessary to
duplicate the physical file before duplicating the logical
file. In this case, the duplicated logical file is based on
the same physical file as was the original logical file.
Unlike the first case, even if the physical file is copied
into the new library before the logical file is copied, the
duplicated logical file is based on the original physical
file, not on the duplicated physical file.

I swear the Help used to say you should always check the database relations after using CRTDUPOBJ on a LF...
because you shouldn't trust it.

only print this email if really necessary Jeffrey TICKNER Technical Resource jtickner@xxxxxxxxxxxxxxxxx

55, rue Adrastée - Parc Altais F-74650 1, Phoenix Mill Lane - Suite 203 -
CHAVANOD Peterborough NH 03458 - USA
Tel. +33 (0)4 50 57 83 96 Tel. + 1 603 371 9074 ext 505
Cell. +33 (0)6 11 15 69 59 Toll. free +1 800 676 4709 ext 505

***This e-mail and its attached documents are confidential and intended solely for the use of the addressee(s). ARCAD Software can in no way be held responsible for any damage resulting from an incident involving security, integrity, virus or transmission delay. As the integrity of this message cannot be guaranteed on Internet, the ARCAD Software company cannot be held responsible for its contents. Any unauthorized use or dissemination is prohibited.***




--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list To post a message email: MIDRANGE-L@xxxxxxxxxxxx To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx Before posting, please take a moment to review the archives at http://archive.midrange.com/midrange-l.



--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list To post a message email: MIDRANGE-L@xxxxxxxxxxxx To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx Before posting, please take a moment to review the archives at http://archive.midrange.com/midrange-l.




As an Amazon Associate we earn from qualifying purchases.

This thread ...

Follow-Ups:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.