I have just received a replacement disk from IBM to replace one that has
failed in my Model 270. I have done the following procedures after manual
IPL:



1. logically remove failed disk from raid
2. stop raid
3. power off.
4. physically remove failed disk and replace it with new one
5. power on system and then attempt to add the new unconfigured disk



This is where I get an error 'Disk Unit I/O failure, check reference code.'

Upon display I get the following information.



The System encountered an error while it was attempting to read or write to
a disk unit.



Contact your Service Representative with the following information.



S/N Type Model Resource Reference Codes

Name I/O
Device


Processor

68-0380C3F 6717 050 DPH001 0000
3110



My concern is that this is the 2nd replacement disk that IBM have send me
that has failed. Does the information above help me pinpoint a different
error or do I just have to ask IBM for another disk.



thanks



Andy


As an Amazon Associate we earn from qualifying purchases.

This thread ...

Follow-Ups:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.