Thanx for the help.

I disabled AUTOCLEAN, and it does what I expect it to do now.



Thanx,

Nick



Nick Radich
Sr. Programmer/Analyst
EPC Molding, Inc.
Direct (320) 679-6683
Toll free (800) 388-2155 ext. 6683
Fax (320) 679-4516
nick_radich@xxxxxxxxxxxxxx



<lgoodbar@xxxxxxxxxxxxxx>
Sent by: midrange-l-bounces@xxxxxxxxxxxx
03/24/2008 03:31 PM
Please respond to
Midrange Systems Technical Discussion <midrange-l@xxxxxxxxxxxx>


To
<midrange-l@xxxxxxxxxxxx>
cc

Subject
RE: IBM 3581 tape drive and Slot 7






Your unit is probably set to automatically use a cleaning tape, which
loads in slot 7.

PP 89-90 in the setup, operator, and service guide say:

Determining the status of the autoclean function:
1. Ensure display is LDR READY.
2. Press and hold NEXT then MODE buttons until DIAG MENU appears.
3. Press SELECT. The message that displays acts as a query about the
status that you want to set:
. If SET AC ON displays, the autoclean function is off.
. If SET AC OFF displays, the autoclean function is on.
4. Press MODE to return to LDR READY.

To disable autoclean (if above said SET AC OFF):
1. Ensure display is LDR READY.
2. Press and hold NEXT then MODE buttons until DIAG MENU appears.
3. Press MODE until AUTOCLEAN appears.
4. Press SELECT. SET AC OFF displays.
5. Press SELECT to disable the AUTOCLEAN function.
. The cleaning slot will ejected.
6. Remove the cleaning cartridge and press SELECT. LDR READY displays.

HTH,
Loyd



Loyd Goodbar
Senior programmer/analyst
BorgWarner
TS Water Valley
662-473-5713

-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx
[mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of
Nick_Radich@xxxxxxxxxxxxxx
Sent: Monday, March 24, 2008 15:00
To: midrange-l@xxxxxxxxxxxx
Subject: IBM 3581 tape drive and Slot 7

Hello everyone,

Hope you all had a nice Easter.

I have an IBM 3581 H13 LT01 tape drive.

It works fine except, when I load all 7 slots ( I don't use a bar code
reader in it) it does not automatcally load slot 7.

It is setup to run Sequentially, the SEQ READY message is displayed.

I have tried testing it by putting tapes in slots 6 and 7, and then
backing up a library using SAVLIB, with ENDOPT(*UNLOAD). It backs up
onto
slot 6, the tape is ejected, but slot 7 does not load.

If I manually load slot 7, I can backup on it using the same SAVLIB
options, but it does not automatically unload. The status msg states
SEQ
DONE. I have to manually unload slot 7.

I have looked through the manuals to no avail. It seems I have
everything
setup correctly.

Does anyone know what might be wrong.

We are at V4R5 of the OS.



Thanx,

Nick



Nick Radich
Sr. Programmer/Analyst
EPC Molding, Inc.
Direct (320) 679-6683
Toll free (800) 388-2155 ext. 6683
Fax (320) 679-4516
nick_radich@xxxxxxxxxxxxxx



As an Amazon Associate we earn from qualifying purchases.

This thread ...

Replies:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.