I'm analyzing elapsed times for jobs, using the data in the several QHST* files on a system. I copy the first record for the CPF1124 & CPF1164 messages into one file, and the third record for the CPF1164 message into another file. I take the first 8 bytes and convert to a timestamp - that value is the join ID for the rows for a given message, but it is the MI TOD for the time the message was sent, so it seems it is usable for start and end time for the job.

What I see is that some jobs, mostly server jobs, have multiple end times for the same start time, same job. Here is an example of counts for grouping by job name, job number, and start time.

PCDMAA 863696 2008-03-03-11.58.24.361112 7
QTCPIP 743863 2008-03-02-10.23.47.283288 17
QSQSRVR 458037 2008-02-28-18.38.12.996880 2

The first job is an interactive job - the others are server things.

So what's up? Fortunately, this behavior does not affect the stuff I'm analyzing, just curious.

Thanks
Vern


As an Amazon Associate we earn from qualifying purchases.

This thread ...

Follow-Ups:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.