Best way, so that you don't have to modify any code to turn it off/on, is 
to find out which *JOBD is used to start the job.  Then do a 
CHGJOBD JOBD(YourJobDescriptionHere) LOG(4 0 *SECLVL) LOGCLPGM(*YES)
That will log everything.  You can adjust those settings if you only want 
to see messages with a certain severity level.  If the jobd gets too 
cluttered with escape message you don't give a shiv about then I'd 
recommend looking at the following code:
 MONMSG CPF9801 EXEC(DO) /* Object does not exist */
   /* Remove message from cluttering joblog */
   RCVMSG MSGTYPE(*NEXT) MSGKEY(*TOP) RMV(*YES) KEYVAR(&KEYVAR) +
          MSGDTA(&DATA) MSGID(&MSGID)
 EndDo

There's an RPG equivalent for Monitor structures.


Rob Berendt

As an Amazon Associate we earn from qualifying purchases.

This thread ...

Replies:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].